Keil uVision2 platform based on the C51 to control the temperature of the source code of the aging chamber. 1, temperature sensors collecting temperature 2, sensor signal incoming ADC circuit 3, after analysis of treatment AT89C52 MCU output control 4, through the relay to control heat, cooling and ventilation unit