Function is (with Verilog language, the more detailed comments): (1) counter function is from 0 to 9999 counts, and are able to form a decimal number on the seven-segment LED display (including the seven-segment LED display module). (2) The counter has a one nclr and a adj_plus side, under the action of the control signal (see below), the counter has reset, increase or decrease of count pause function. Complete the preparation of the above program modules. Counter function menu nclr adj_minus reset 0 0 0 0 1 1 0 counts counting suspended Count