Description: 有源滤波器(APF)matlab_simulink仿真图的子图之一。算法是DQ0 算法。-active filter (APF) matlab_simulink simulation map one of the graph. The algorithm is DQ0 algorithm. Platform: |
Size: 5120 |
Author:王晓光 |
Hits:
Description: 基于谐波电流快速检测方法的并联型有源电力滤波器设计。用于毕业设计-Harmonic Current Detection Method Based Shunt Active Power Filter. For graduation Platform: |
Size: 4926464 |
Author:杨强 |
Hits:
Description: 基于谐波电流快速检测方法的并联型有源电力滤波器设计 不错的 可以做毕业设计-Harmonic Current Detection Method Based Shunt Active Power Filter can do a good graduation Platform: |
Size: 4582400 |
Author:杨强 |
Hits:
Description: 基于谐波电流快速检测方法的有源电力滤波器simulink仿真模型
-Current rapid detection methods based on harmonic active power filter simulink simulation model Platform: |
Size: 14336 |
Author:流沙 |
Hits:
Description: Abstract—In this paper a current reference generation
method for a voltage source shunt active power filter is
examined. The proposed method improves the harmonic
filtering by compensating the delays in the system. In
stationary operating point of the load the method uses
measurement data sampled in previous periods to generate a
reference prediction. Since in transient state of the load the
prediction no longer holds true, a computational control delay
compensation algorithm is used in the reference generation
instead of the prediction in this situation. Changing the
algorithm according to the operating point guarantees effective
harmonic compensation in all operating points. In this paper
the system performance is examined with an active filter
simulation model. Platform: |
Size: 274432 |
Author:yasser |
Hits:
Description: 基于pq谐波电流检测的三相三线制有源滤波器模型。-Pq harmonic current detection based on three-phase three-wire active filter model. Platform: |
Size: 20480 |
Author:Qiu lin |
Hits:
Description: This paper deals with an innovating Shunt active
filter with PI controller for harmonic elimination . Active filter
provide a viable solution to mitigating harmonic issues caused by
the non linear loads .The active filter compensates the reactive and
harmonic currents drawn by the non-linear loads besides power
factor correction Platform: |
Size: 246784 |
Author:mahesh |
Hits:
Description: 有源电力滤波器,用于实现无功治理与谐波补偿,精度很高-Active power filter for reactive power control and harmonic compensation, high accuracy Platform: |
Size: 12288 |
Author:hanwei |
Hits:
Description: 采用改进遗传算法,对无源滤波器的成本、无功补偿和滤波效果三个方面进行参数优化-parameters of the hybrid active power filter for its cost,harmonic suppression and effect of filtering are optimized by refined genetic algorithm Platform: |
Size: 418816 |
Author:小甜瓜 |
Hits:
Description: High penetration of wind energy into the grid may introduce stability and power quality problems due to the fluctuating nature of the wind and the increasing complexity of the power system. By implementing advanced functionalities in power converters, it is possible to improve the performance of the wind farm and also to provide grid support, as it is required by the grid codes. One of the main compliance difficulties that can be found in such power plants are related to reactive power compensation and to keep the harmonics content within the allowed limits, even if the power of the WPP converters is increasing. This paper deals with an advanced control strategy design of a three-level converter performing STATCOM and Active Filter functionalities. A novel control strategy called Smart-STATCOM is introduced, since it has the capability of self-controlling reactive power and harmonic voltages at the same time. Platform: |
Size: 3078144 |
Author:hocine |
Hits:
Description: This paper presents a new control scheme for a
hybrid parallel active filter (HPAF) system intended for highpower
applications—up to 100-MW nonlinear loads—to meet
IEEE 519 recommended harmonic standards Platform: |
Size: 430080 |
Author:mak |
Hits:
Description: In this paper, an efficient active power filter (APF) scheme is developed to estimate and compensate for harmonic distortion in an electrical power network. The developed APF control scheme is based on a double proportional feedback controller and a single-phase voltage-source half-wave bridge inverter. The proposed filter uses a Multi-layer Artificial Neural Network (MLANN) with a shift method for estimating system harmonic currents and voltages at a dedicated point. The proposed scheme is tested on a 13 bus industrial distribution system. The obtained results ensure the effectiveness of the proposed filter. The system is simulated in MATLAB-Simulink and simulation results prove that the polluting harmonics have been greatly reduced. Platform: |
Size: 1906688 |
Author:amir1 |
Hits: