Welcome![Sign In][Sign Up]
Location:
Search - ac to ac inverter matlab

Search list

[SCMzhihuanbijiaopwm

Description: 滞环比较逆变器,生产交流电压波形比较好,大家下来玩玩吧-Comparison of hysteresis inverter, the production of AC voltage waveform is better, everyone down to play it
Platform: | Size: 10240 | Author: ren | Hits:

[Energy industrydanxiangquanqiao

Description:
Platform: | Size: 10240 | Author: sjw | Hits:

[matlabMatlab-simulink-inverter

Description: 基于Matlab/simulink的交-交变频器仿真研究-Based on Matlab/simulink delivery- AC Inverter Simulation
Platform: | Size: 195584 | Author: Amberfay | Hits:

[DSP programPhotovoltaic-Inverter-BASED-2812dsp

Description: 针对光伏并网发电系统中关健部件—逆变器的结构设计与控制方法研究进行了详细分析 和阐述。从电网、光伏阵列以及用户对逆变器的要求出发, 分析了各种不同的逆变器拓扑结构与控 制方法, 比较其运行效率和控制效果。对于本文提出了一种基于全桥变换器的正弦波逆变电源的整体设计 方案。文章首先对系统设计中将使用到的DC/DC变换器,DC/AC变 换器以及PWM控制技术在理论上进行了深入的研究。并讨论了数字 式PID控制算法的实现和在系统中的应用,还针对这种基于全桥变换 器的正弦波逆变器提出了一种用一个电压闭环来调节两个控制量的 PID算法。 其次,文章设计了基于全桥变换器、全桥逆变器和以DSP为核 心的逆变电源控制电路,详细介绍了各相关电路模块的原理与结构。 在完成电路参数设计以后,通过使用MATLAB/Simulink软件对整个 系统进行了仿真分析。并对系统软件设计的思路与实现方法以及关键 程序的流程进行了介绍。 最后,通过系统的带载实验对整套系统软硬件设计的合理性进行 了验证。实验结果表明,本文设计的逆变电源硬件电路和软件系统是 成功的。 -The paper comes up with a full-package solution to convert solar power into AC.This solution is based on the design of the full-bridge converter and the full-bridge inverter.This paper first gives full analysis on the theories of power switching technology,inverter technology and PWM technology.And the theory and fulfillment of PID algorithm are discussed in this paper.Especially for this solution,this paper comes up with a PID algorithm in which two variables are being controlled in one close-loop. Then,this paper gives the procedure to calculate the main circuit parameters.The design of digital controlling circuit and assistant circuits, such as MOSFET driving circuit and voltage protection circuit,are introduced.Based on the parameters worked out,the paper gives the simulation of whole system in Matlab/Simulink.This paper also introduces the firmware design based on the DSP(TMS320F2812). The last is the verification of whole system including hardware and software by t
Platform: | Size: 1939456 | Author: fmx | Hits:

[matlabmohu-dirct-torque

Description: 该仿真模型是一种利用模糊控制器调节PWM信号占空比的异步电动机直接转矩控制的策略,即在传统异步电动机直接转矩控制的基础上,用模糊控制器代替传统DTC中的滞环比较器和空间电压矢量状态选择器来细分控制规则,最后控制逆变器的开关,以减小转矩和磁链脉动,从而改善交流异步电机伺服系统的动、静态品质,使整个系统具有较强的鲁棒性和自适应性。-A method of the stator resistance estimate which based on the fuzzy neural network was proposed and the motor speed is estimated by MRAS speed identification algorithm based on the stator voltage and the current that can be easily detected. Besides, a new design of fuzzy direct torque control system of induction motor was introduced in this paper, which based on strategy of modulating the duty cycle to decrease the torque and stator flux ripple. This design uses fuzzy control block to instead of the traditional space voltage vector selector to control the inverter switch which can improve the static and dynamic performances of AC asynchronous motors, which make the whole control system have strong robustness.
Platform: | Size: 14336 | Author: 王晨 | Hits:

[matlabSPWM-voltage-invertor

Description: :SPWM调制技术是通过改变输出方波的占空比来改变等效的输出电压,其调制波为正弦波,脉冲宽度间占空 比按正弦规率排列, 这样输出波形经过适当的滤波可以做到正弦波输出。它广泛的用于支流交流逆变器。本次实 验使用Matlab/Simulink对SPWM技术进行仿真并分析数据。-: SPWM modulation by changing the duty cycle square wave output to change the equivalent output voltage, the modulated sine wave, pulse width, duty cycle between the rate at sine arranged so that the filter output waveform can be done properly to the sine wave output. It is widely used in branch AC inverter. The experiment uses Matlab/Simulink simulation of the SPWM technique and analyze data.
Platform: | Size: 651264 | Author: fmx | Hits:

[Software EngineeringContentServer

Description: 矢量控制与直接转矩控制是当前主要的两种电机变频调速控制方法,已在两相交流感应电机中得到 了应用。分析了两相不对称电机矢量控制和直接转矩控制原理以及两相三桥臂逆变器的SVPWM实现方法; 运用Matlab的Simulink建立了两相不对称交流感应电机矢量控制和直接转矩控制调速系统的仿真模型,并 对两种控制系统进行了仿真研究,给出了仿真波形,进行了特性比较. 关键词:两相电机;矢量控制;直接转矩控制;SVPWM;MATLAB;仿真-Vector Control and Direct Torque Control is currently the main method of frequency control of two motors, has been in two-phase AC induction motor has been applied. Analysis of asymmetric two-phase motor vector control and direct torque control principle and two-phase SVPWM inverter arm Bridge Implementation the use of Matlab in Simulink to establish a two-phase AC induction motor asymmetry of vector control and direct torque control modulation speed of system simulation models, and the two control system was simulated, the simulation waveform characteristics were compared. Key words: two-phase motor vector control direct torque control SVPWM MATLAB Simulation
Platform: | Size: 153600 | Author: 卢维津 | Hits:

[OtherSTATCOM

Description: In a deregulated utility environment financial and market forces will demand a more optimal and profitable operation of the power system with respect to generation, transmission and distribution. Power electronic equipment such as flexible AC Transmission systems (FACTS) opens up new opportunities for controlling power and enhancing the usable capacity in the existing system. A Static synchronous compensator (STATCOM) based on the voltage Sourced inverter is a widely used shunt FACTS device. This paper deals with the basic simulation of STATCOM for two machine system and demonstration of transient stability enhancement using STATCOM through Matlab/Simulink/Power system Computer Aided design (PSCAD).
Platform: | Size: 19635200 | Author: Kandiban Rajendran | Hits:

[matlabGCPPP

Description: Grid-connected distributed generation sources interfaced with voltage source inverters (VSIs) need to be disconnected the grid under: 1) excessive dc-link voltage 2) excessive ac currents and 3) loss of grid-voltage synchronization. In this paper, the control of single- and two-stage grid-connected VSIs in photovoltaic (PV) power plants is developed to address the issue of inverter disconnecting under various grid faults. Inverter control incorporates reactive power support in the case of voltage sags based on the grid codes’ (GCs) requirements to ride-through the faults and support the grid voltages. A case study of a 1-MW system simulated in MATLAB/Simulink software is used to illustrate the proposed control. Problems that may occur during grid faults along with associated remedies are discussed. The results presented illustrate the capability of the system to ride-through different types of grid faults.-Grid-connected distributed generation sources interfaced with voltage source inverters (VSIs) need to be disconnected the grid under: 1) excessive dc-link voltage 2) excessive ac currents and 3) loss of grid-voltage synchronization. In this paper, the control of single- and two-stage grid-connected VSIs in photovoltaic (PV) power plants is developed to address the issue of inverter disconnecting under various grid faults. Inverter control incorporates reactive power support in the case of voltage sags based on the grid codes’ (GCs) requirements to ride-through the faults and support the grid voltages. A case study of a 1-MW system simulated in MATLAB/Simulink software is used to illustrate the proposed control. Problems that may occur during grid faults along with associated remedies are discussed. The results presented illustrate the capability of the system to ride-through different types of grid faults.
Platform: | Size: 38912 | Author: hari | Hits:

[Otherpower_1phPWM

Description: PWM波实现直流变成交流的逆变,基于MATLAB软件,且几桥臂是可以按自己要求选择的-PWM WAVE DC to AC inverter, based on MATLAB software, and a few arm can be chosen according to their own requirements
Platform: | Size: 12288 | Author: llw | Hits:

[File Format129-Study-of-an-AC-side-wind-energy-system-conver

Description: This Paper consists on the study of one part of wind energy system conversion, its AC side. Renewable resources are in constant fluctuation. This situation could put in peril the energizing efficiency towards a given demand requirement. Therefore, in order to maximize the efficiency of the renewable energy system, it is necessary to track the maximum power point of the input source, a study established under MATLAB/Simulink platform. For the wind system, the maximizing is assured while considering the optimal power curve as load characteristic, with the knowledge of the turbine characteristic Cp (λ). Then, this work elaborates the analysis and simulation of a low speed Permanent Magnet Synchronous Generator (PMSG) driven by a vertical wind turbine through a Pulse-Width Modulation (PWM) voltage inverter, independently of the DC components of the wind system conversion, using MATLAB computer simulation. -This Paper consists on the study of one part of wind energy system conversion, its AC side. Renewable resources are in constant fluctuation. This situation could put in peril the energizing efficiency towards a given demand requirement. Therefore, in order to maximize the efficiency of the renewable energy system, it is necessary to track the maximum power point of the input source, a study established under MATLAB/Simulink platform. For the wind system, the maximizing is assured while considering the optimal power curve as load characteristic, with the knowledge of the turbine characteristic Cp (λ). Then, this work elaborates the analysis and simulation of a low speed Permanent Magnet Synchronous Generator (PMSG) driven by a vertical wind turbine through a Pulse-Width Modulation (PWM) voltage inverter, independently of the DC components of the wind system conversion, using MATLAB computer simulation.
Platform: | Size: 192512 | Author: zakary | Hits:

[matlab04272405

Description: A photovoltaic array (PVA) simulation model to be used in Matlab-Simulink GUI environment is developed and presented in this paper. The model is developed using basic circuit equations of the photovoltaic (PV) solar cells including the effects of solar irradiation and temperature changes. The new model was tested using a directly coupled dc load as well as ac load via an inverter. Test and validation studies with proper load matching circuits are simulated and results are presented here.
Platform: | Size: 189440 | Author: Prithvi | Hits:

[OtherGridStorageBatt

Description: From the late nineteenth century through the middle of the twentieth century, DC-to-AC power conversion was accomplished using rotary converters or motor-generator sets (M-G sets). In the early twentieth century, vacuum tubes and gas filled tubes began to be used as switches in inverter circuits. The most widely used type of tube was the thyratron. The origins of electromechanical inverters explain the source of the term inverter. Early AC-to-DC converters used an induction or synchronous AC motor direct-
Platform: | Size: 14336 | Author: SOLARA | Hits:

[Windows DevelopLi_ion_battery

Description: From the late nineteenth century through the middle of the twentieth century, DC-to-AC power conversion was accomplished using rotary converters or motor-generator sets (M-G sets). In the early twentieth century, vacuum tubes and gas filled tubes began to be used as switches in inverter circuits. The most widely used type of tube was the thyratron. The origins of electromechanical inverters explain the source of the term inverter. Early AC-to-DC converters used an induction or synchronous AC motor
Platform: | Size: 301056 | Author: SOLARA | Hits:

[Booksbackstepping

Description: The objective is to present a nonlinear approach to design a suitable controller system for the photovoltaic (PV) single-phase grid-connected system. The system structure includes a PV generator, Boost converter, and DC-AC inverter coupled to grid network. A backstepping controller is developed to extract maximum point power tracking (MPPT), to regulate the DC bus voltage, and to generate a sinusoidal current into the grid in phase with grid voltage in order to achieve unity power factor. The stability of the control algorithm is demonstrated by tools of Lyapunov analysis. Simulations show that the proposed controller system completely accomplishes listed aims even under atmospheric conditions variation. Theperformance of the proposed controller has been validated by numerical simulation in MATLAB SIMULINK(The objective is to present a nonlinear approach to design a suitable controller system for the photovoltaic (PV) single-phase grid-connected system. The system structure includes a PV generator, Boost converter, and DC-AC inverter coupled to grid network. A backstepping controller is developed to extract maximum point power tracking (MPPT), to regulate the DC bus voltage, and to generate a sinusoidal current into the grid in phase with grid voltage in order to achieve unity power factor. The stability of the control algorithm is demonstrated by tools of Lyapunov analysis. Simulations show that the proposed controller system completely accomplishes listed aims even under atmospheric conditions variation. Theperformance of the proposed controller has been validated by numerical simulation in MATLAB SIMULINK)
Platform: | Size: 507904 | Author: zinouzinou | Hits:

CodeBus www.codebus.net